title: UVAL Wired | Products | BuildingGT
description: Measure thermal transmittance with the UVAL Wired system for reliable U-Value information. Get calibrated, plug-and-play solution for building industry. Buy now!
---

[Skip to content](https://info.greenteg.com/building/uval-wired#main-content)

[![uval_logo_positiv_rgb-1](https://info.greenteg.com/hs-fs/hubfs/uval_logo_positiv_rgb-1.png?width=140&height=50&name=uval_logo_positiv_rgb-1.png "uval_logo_positiv_rgb-1")](https://info.greenteg.com/building?hsLang=en)

- [Home](https://info.greenteg.com/building?hsLang=en)
- Products
  
  ##### [![UVAL Wireless - Homepage](https://info.greenteg.com/hs-fs/hubfs/UVAL%20Wireless%20-%20Homepage.png?width=100&name=UVAL%20Wireless%20-%20Homepage.png) UVAL Wireless Explore our wireless system for accurate and remote U-Value measurement.](https://info.greenteg.com/building/uval-wireless?hsLang=en)
  
  ##### [![UVAL Wired Kit Adjusted Ratio](https://info.greenteg.com/hs-fs/hubfs/UVAL%20Wired%20Kit%20Adjusted%20Ratio.png?width=100&name=UVAL%20Wired%20Kit%20Adjusted%20Ratio.png) UVAL Wired Explore our wired system for accurate U-Value measurement.](https://info.greenteg.com/building/uval-wired)
  
  ##### [UVAL Wired vs UVAL Wireless Discover the key differences between our two U-value measurement systems.](https://info.greenteg.com/building/uval-wired-vs-uval-wireless?hsLang=en)
- Applications 
  
    - [Building Performance Assessments](https://info.greenteg.com/building/building-performance-assessments?hsLang=en)
    - [Retrofit Evaluation and Decisions](https://info.greenteg.com/building/retrofit-evaluation-decisions?hsLang=en)
    - [Building Envelope Insulation Development](https://info.greenteg.com/building/building-envelope-insulation?hsLang=en)
    - [Energy Model Validation](https://info.greenteg.com/building/energy-model-validation?hsLang=en)
    - [View All Applications](https://info.greenteg.com/building/applications?hsLang=en)
- Library 
  
    - [Publication Highlights](https://info.greenteg.com/building/publication-highlights?hsLang=en)
    - [Whitepapers](https://info.greenteg.com/building/whitepapers?hsLang=en)
    - [Downloads](https://info.greenteg.com/building/downloads?hsLang=en)
    - [FAQ](https://info.greenteg.com/building-faq?hsLang=en)
- About 
  
    - [Technology](https://info.greenteg.com/building/technology?hsLang=en)
    - [Team](https://info.greenteg.com/building/team?hsLang=en)
    - [Contact Us](https://info.greenteg.com/building/contact-us?hsLang=en)
- [Shop](https://shop.greenteg.com/building/)

PRODUCT

# UVAL Wired System

UVAL Wired is a calibrated and plug-and-play solution that allows you to measure the thermal transmittance of a material or assembly for the building industry.

Our measurement approach uses a heat flux sensor and two temperature sensors. This method is standardized in ISO 9869, ASTM C1046, and ASTM C1155. It is a proven method that delivers reliable quantitative in-situ U-Value information of a building envelope.

*CHF 1,949.00 per system*

[Order Now](https://shop.greenteg.com/u-value/)

![UVAL Wired Kit](https://27184589.fs1.hubspotusercontent-eu1.net/hub/27184589/hubfs/UVAL%20Wired%20Kit.png?width=1200&length=1200&name=UVAL%20Wired%20Kit.png)

![UVAL Wired - Kit](https://27184589.fs1.hubspotusercontent-eu1.net/hub/27184589/hubfs/UVAL%20Wired%20-%20Kit.png?width=1200&length=1200&name=UVAL%20Wired%20-%20Kit.png)

UVAL Wired - Kit

![UVAL Wired - Data Logger](https://27184589.fs1.hubspotusercontent-eu1.net/hub/27184589/hubfs/UVAL%20Wired%20-%20Data%20Logger.png?width=1200&length=1200&name=UVAL%20Wired%20-%20Data%20Logger.png)

UVAL Wired - Data Logger

![UVAL Wired -  Heat Flux Sensor](https://27184589.fs1.hubspotusercontent-eu1.net/hub/27184589/hubfs/UVAL%20Wired%20-%20%20Heat%20Flux%20Sensor.png?width=1200&length=1200&name=UVAL%20Wired%20-%20%20Heat%20Flux%20Sensor.png)

UVAL Wired -  Heat Flux Sensor

## Product Details

Features

- Calibrated Plug-and-Play solution
- Measurement of U-value (W/(m²K)), heat flux (W/m²), and 2 temperatures (°C)
- Compatible with standards ISO 9869 and ASTM C1046 /ASTM C1155
- Stores up to 2 million data points
- Battery lifetime >1 month
- High-sensitive thermal detectors
- Compact design
- USB interface

Inclusions

**Device**:   
1 gSKIN® Heat Flux Sensor   
1 gSKIN® DLOG Data Logger with 2 temperature sensors

**Accessories:**   
1 USB cable (PC to data logger)   
1 Roll of Double-Sided Adhesive Tape

**Instructions and Manual:**   
1 Calibration sheet   
1 Instruction manual

Software will be provided via password-protected download link (compatible with Windows OS only).

Specifications

**Article Number**: A-163479

**Heat Flux Range Min / Max \[W/M²\]:** ±300

**Heat Flux Resolution \[W/M²\]:** <0.22

 

**Temperature Accuracy \[°C\]**: ±0.5 (-10...+46 °C) ±2.0 (-55...+125 °C)

 

**Min. Sensor Sensitivity (S) \[ΜV/(W/M²)\]**: 7.0 (sensor calibration data already loaded onto logger for simple and fast plug-and-play measurements).

 

**Data Storage Capacity \[# Measurements\]:** >2’000’000

 

**Battery Lifetime \[Days\]:** >30 at lowest measurement frequency (2/d). Rechargeable.

 

**Logger Dimensions (Mm)**: 52 x 20 x 15

 

**Bit Resolution \[Bits\]**: 12

 

**Operation Modes**: Autonomous / Live

 

**Operating Temperature Range Min/Max \[°C\]:** -40 / 100 (-25 / 65 for Logger)

 

**Operating System:** Windows 2000 / XP / Vista / 7 / 8

 

**Calibration Accuracy \[±%\]:** 3 (Sensor calibration data already loaded onto logger for simple and fast plug-and-play measurements).

 

**Calibration Temperature Range Min/Max** \[°C\]: -30 / 70

 

**Heat Flux Sensor Cable Length \[M\]**: 1.5 (with connector)

 

**Temperature Sensor 1 / 2 Cable Length \[M\]**: 5.0 / 1.0

 

**Measurement Frequency**: 1/s to 1/h

 

**Computer Interface**: USB

#### Brochure

Explore the comparison between UVAL Wired and Wireless Systems

 Download

#### Case Studies

 Real-world applications demonstrating product efficiency

[Read](https://info.greenteg.com/building/publication-highlights?hsLang=en)

### Product Manual

Guide for product and software setup, installation, and operation

 Download

### Frequently Asked Questions

Didn't find what you're looking for? Feel free to<https://info.greenteg.com/building/uval-wired#uvalwireless-contact>send us an e-mail or book a meeting<https://info.greenteg.com/building/uval-wired#uvalwireless-contact> with our expert.

Can I take the U-Value of glass?

Both of our system models feature a CSV export function, enabling comprehensive analysis of measurements. We also provide an adaptable Excel template upon request, which you can use to further tailor and analyze your data.

What interior building conditions should I watch out for?

The following conditions can affect readings: 

- Proximity to Heating and AC Devices
- Room Occupancy
- Drafts
- Mold Presence

What exterior building conditions should I watch out for?

Direct sunlight should be avoided on the sensors. greenteg’s node and outdoor sensors are rated IP67.

What's the minimum period for an ISO calculation?

72 hours, however ideally you need at least 96 hours

[More FAQ](https://info.greenteg.com/building-faq?hsLang=en)

#### Have more questions?

Looking for more information about the product or interested in a personalized quote? Fill out the form below, and we’ll get back to you as soon as possible.

- [Home](https://info.greenteg.com/building)
- [Corporate Page](https://greenteg.com/)
- [Shop](https://shop.greenteg.com/)

Hofwisenstrasse 50A, CH-8153 Rümlang ZH, Switzerland  
©2024 greenteg AG - All rights reserved

Contact us 

[E-mail or schedule a meeting](https://info.greenteg.com/building/contact-us?hsLang=en)

Follow us on social media!

<https://www.linkedin.com/company/greenteg-ag/> <https://x.com/greentegag>